Seattle energy code c405.10
Web1 Jul 2024 · Section C405.9 — Vertical and horizontal transportation systems. HTML PDF: 51-11C-40510: Section C405.10 — Controlled receptacles. HTML PDF: 51-11C-40511: … Web31 May 2024 · C405.10 Controlled receptacles (Mandatory). At least 50 percent of all 125 volt 15- and 20-ampere receptacles installed in private offices, open offices, conference rooms, rooms used primarily for printing and/or copying functions, break rooms, individual workstations and classrooms, includ-
Seattle energy code c405.10
Did you know?
Web13 Oct 2015 · C405.4: Lighting Power Density changes • C405.10 Controlled Receptacles in certain occupancies • C406: Additional Efficiency Package Options: 2 points • C407: Energy Modeling Compliance Path changes • C408: Commissioning changes • C409: Energy Metering clarifications • “Capable of” changed to “Configured to” in 55 locations Web24 Sep 2024 · For this example, let's say we have a Group B occupancy with 100 parking spots - according to Table C405.10.2, we will need 10% of spaces to be EV ready spaces, another 10% of spaces to be EV capable, and only 5% of spaces to have an installed EV charger. Level 2 Chargers Only: EV Ready 10 Spots EV Capable 10 Spots
Web1 Jan 2024 · 2015 Seattle Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised Nov 2024 Project Info Project Title: Date 10/5/2024 ... sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide … Web2015 SEATTLE ENERGY CODE C-23 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY SECTION C401 GENERAL C401.1 Scope. ... C405.9, C405.10, C405.13, C408, C409, C410, and C412. The building energy consumption shall be equal to or less than 87, 90 or 93 percent of the standard reference design build-ing, depending on the option selected per …
WebC405.2.1.2 Occupant Sensor Control Function in Warehouses In warehouses, the lighting in aisleways and open areas shall be controlled with occupant sensors that automatically …
Web27 Jan 2014 · Occupancy sensors per C405.2.2.2 are required in all classrooms, conference/meeting rooms, employee lunch and break rooms, private offices, restrooms, storage rooms, janitorial closets, and other spaces 300 sq ft or smaller enclosed by ceiling height partitions.
WebVersion 1 of NYStretch Energy Code-2024 (NYStretch) is an overlay of the 2024 International Energy Conservation Code (2024 IECC) and ASHRAE Standard 90.1-2016 (ASHRAE). It does not reflect changes the New York State Fire Prevention and Code Council may adopt for the 2024 New York State Energy Conservation Construction Code (2024 NYS ECCC). Visit scp 049 without a maskWebSection C405.10 — Controlled receptacles. C405.10 Controlled receptacles. At least 50 percent of all 125 volt 15- and 20-ampere receptacles installed in private offices, open … scp 049 x reader lemonsWeb26 Aug 2024 · What the Seattle Energy Code Requires “Controlled receptacles” are electrical outlets that are automatically turned on and off by occupancy sensors or time switch … scp 049 womanWebStandard Referenced reference in code number Title section number 10 CFR, Part 430—1998 Energy Conservation Program for Consumer Products: Test Procedures and Certification … scp 054 water nymph scp animationWebWelcome to MBP MBP scp 049 without suitWeb2015 SEATTLE ENERGY CODE C-147 INDEX Changes from the index in the Washington State Energy Code are not shown in underline and strikeout. A ACCESSIBLE Controls . . . . … scp 049 voice changer windowsWeb• C405.2.5 – Daylight-responsive controls required in all daylight zones. In other words, the lights have to turn down when daylight is available. • C405.2.7 – Most exterior lighting has … scp 053 and scp 096